| AAQL | BODY STYLE | |
| ADAQ | BODY LENGTH | INCHES MINIMUM 1.985 AND INCHES MAXIMUM 2.015 |
| ADAT | BODY WIDTH | INCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760 |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 1.550 AND INCHES MAXIMUM 1.570 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES MINIMUM 1.650 AND INCHES MAXIMUM 1.670 |
| AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJEC | BOSS HEIGHT | INCHES MINIMUM 0.120 AND INCHES MAXIMUM 0.140 |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MINIMUM 1.870 AND INCHES MAXIMUM 1.890 |
| AKPX | POLE QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 2 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES DC 30.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 250.0 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 1000.0 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC-HYDRAULIC |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | ALARM 1 |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.138 |
| CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 2.200 AND MAXIMUM AT 200 PCT 20.000 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT |
| CRTK | SWITCH TERMINAL TYPE | QUICK DISCONNECT, MALE |
| CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | AC 1.5 AND DC 0.05 |
| CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 250.0 AND DC 24.0 |
| FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 |
| MATT | MATERIAL | CASE PLASTIC |
| PMLC | PRECIOUS MATERIAL AND LOCATION | SILVER CONTACT SURFACES |
| PRMT | PRECIOUS MATERIAL | SILVER |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | QUICK DISCONNECT, MALE 3 |